The 5073m automated liquid handling systems is tailored for nucleic acid purification (NAP), but is flexible for other liquid handling tasks. The integrated magnetic finger and ThermoMixer module is ideal for our MagSep reagent kits, saving hands-on time and improving the reproducibility of results. It is controlled by EasyCon tablet or MultiCon PC and can be configured with CleanCap. The M5073 comes with specific tools and accessories for NAP with our MagSep reagent kits. More information

Order Info

show more (3)

Product Information

The epMotion 5073m: 2 systems in one. First, a perfect system for automated nucleic acid purification of 1 to 24 samples with special MagSep reagents. The Eppendorf EasyCon tablet or MultiCon PC and Prep Assistant software provide simple operation with step-by-step guidance through the process. Secondly, it is a flexible system for automating time-consuming and complex pipetting procedures with the epBlue™ software, making routine Liquid Handling tasks easier than ever. The pipetting procedure is more precise, reproducible and fully standardized, making your workplace more ergonomic and safer. The customized epMotion M5073 is delivered with all accessories required for nucleic acid purification; only consumables need to be ordered separately.

Only for epMotion 5073m, M5073, and 5075m: Limited Use Label License
Notice to purchaser; limited license for research use only
This product and its use may be covered by one or more patents owned by Gen-Probe Incorporated. The purchase price for this product includes only limited, nontransferable rights under certain claims of certain patents owned by Gen-Probe Incorporated to use this product for research purposes only. No other rights are conveyed. Purchaser is not granted any rights under patents of Gen-Probe Incorporated to use this product for any commercial use. Further information regarding purchasing a license under patents of Gen-Probe Incorporated to use this product for any other purposes, including, without limitation, for commercial use, may be obtained by contacting Gen-Probe Incorporated, Attn: Business Development Department, 10210 Genetic Center Drive, San Diego, California 92121-4362, U.S.A.

Eppendorf 3D-MagSep™ Technology


The combination of magnetic finger module and ThermoMixer facilitates magnetic separation, mixing, and temperature control in one location.
Used with the specific PrepRack it facilitates DNA or RNA purifications from 1 to 24 samples out of 2-mL Safe-Lock tubes. Magnetic fingers are drawn in or out of the PrepRack allowing mixing, washing, and separation of magnetic beads for nucleic acid purification or various other applications.

epMotion® 5073m

Dedicated reagents kits


Free-up your time for scientific work - Whether your sample is tissue, cells, bacteria, blood
or cell-free body fluids, the MagSep Tissue gDNA, MagSep Blood gDNA or MagSep Viral DNA/RNA kit is your smart solution. The kits are designed for rapid automated small-scale preparation of highly pure nucleic acids based on robust magnetic bead separation using
the epMotion M5073 or 5075m. The ready to use reagents come in 4 special trays for 1–24 preparations each. Benefit from minimal hands-on time with ready to use reagents, special epMotion reagent tray, and easy software assistants. Get superior yield and purity versus manual or other automation methods.

› Automatic recognition of kit type and available reagents
› Variable use of 1–24 sample reagents per tray and intermediate storage possible
› 25–200 µL variable choice of elution volume (concentration vs. yield)
› DNA LoBind Safe-Lock tubes included for maximum DNA recovery

epMotion® 5073m

Reuse Tips Feature


The new epMotion systems can reuse tips as e.g. economical choice for multiple wash steps
of the same well. Here special epT.I.P.S. Motion SafeRack tips are recommended. Pipette tips
will be placed back into the position of the box they were removed from. Returned tips will be reused within an application for the same source vessel.

› Individual compartments in rack to avoid cross-contamination between used tips
› Available as standard and PCR clean quality for 50, 300 and 1000 µL

epMotion® 5073m

Features

  • 6 ANSI/SLAS microplate positions
  • Software assistants for simple, step-by-step application programming
  • Optical sensor1) for detecting liquids, labware, tips
  • Automatic replacement of 2 pipetting tools
  • Volume range of 1 to 1,000 µL for maximum pipetting accuracy
  • 3D-MagSep technology, mixing, tempering, and magnetic separation all at one location
  • Calibrated 1-channel and 8-channel pipetting tools
  • Optional UV lamp and HEPA filter system for decontamination and clean air conditions
  • Compatible with tubes (0.2 to 50 mL) and microplates with up to 384 wells
  • Option for compact EasyCon tablet or MultiCon PC controller by touch, mouse or keyboard, upgradable for barcode tracking and GLP/GMP software versions

1) US patent 6,819,437 B2

Applications

  • DNA and RNA purification
  • PCR set-up
  • Sample or reagent transfer
  • Sample mixing and tempering
  • Assay set-up
  • Media change and other cell culture applications
 epMotion® M5073epMotion® M5073cepMotion® 5073mepMotion® 5073mc
Gripper carrying capacity1,200 g1,200 g1,200 g1,200 g
Mixing frequencyOff, 300 – 2,000 rpm, optimized for labware and applicationOff, 300 – 2,000 rpm, optimized for labware and applicationOff, 300 – 2,000 rpm, optimized for labware and applicationOff, 300 – 2,000 rpm, optimized for labware and application
Mixing period5 s – 120 min5 s – 120 min5 s – 120 min
OperationElectronicElectronicElectronicElectronic
Pipetting typeAir-cushionAir-cushionAir-cushionAir-cushion
Noise level~ 56 dB(A)~ 56 dB(A) HEPA off~ 56 dB(A)~ 56 dB(A)
Heating rate
Cooling rate
Power supply100 – 240 V ±10 %, 50 – 60 Hz ±5 %100 – 240 V ±10 %, 50 – 60 Hz ±5 %100 – 240 V ±10 %, 50 – 60 Hz ±5 %100 – 240 V ±10 %, 50 – 60 Hz ±5 %
Max. power consumption600 W600 W600 W600 W
Dimensions (W × D × H)65 × 61 × 67 cm / 26 × 24 × 27 in65 × 61 × 77 cm / 26 × 24 × 27 in65 × 61 × 67 cm / 26 × 24 × 27 in65 × 61 × 67 cm / 26 × 24 × 27 in
Weight w/o accessories57 kg / 125.6 lb62 kg / 136.7 lb57 kg / 125.6 lb57 kg / 125.6 lb
X-Y-Z axis positioning accuracy    
Random deviation±0.3 mm±0.3 mm±0.3 mm±0.3 mm
Systematic deviation±0.1 mm±0.1 mm±0.1 mm±0.1 mm
ThermoMixer    
Max. load1,000 g (2.2 lb)1,000 g (2.2 lb)1,000 g (2.2 lb)1,000 g (2.2 lb)
Mixing period5 s – 120 min5 s – 120 min5 s – 120 min5 s – 120 min
Speed300 rpm – 2,000 rpm300 rpm – 2,000 rpm300 rpm – 2,000 rpm300 rpm – 2,000 rpm
Temperature range15 °C below RT to 95 °C15 °C below RT to 95 °C15 °C below RT to 95 °C15 °C below RT to 95 °C
Eppendorf EasyCon    
DisplayLCD color displayLCD color displayLCD color displayLCD color display
Display resolution1,024 × 600 pixels1,024 × 600 pixels1,024 × 600 pixels1,024 × 600 pixels
Interfaces4 × USB 2.04 × USB 2.04 × USB 2.04 × USB 2.0
Touch panelCapacitive touch panelCapacitive touch panelCapacitive touch panelCapacitive touch panel
Conductor – X, Y, Z Positioning    
Random measurement error±0.1 mm±0.1 mm±0.1 mm±0.1 mm
Detector    
Optical confocal infrared detectorContact-free recognition of fill level, inserted tools, labware, tip types and quantitiesContact-free recognition of fill level, inserted tools, labware, tip types and quantitiesContact-free recognition of fill level, inserted tools, labware, tip types and quantitiesContact-free recognition of fill level, inserted tools, labware, tip types and quantities
UV lamp    
Irradiation period per run15 min
Main wavelength254 nm (UV-C)
Radiation capacity after 100 h3,9 W
Radiation capacity at a distance of 1 m39 µW/cm2
HEPA filter    
Filter class according to EN 1822E 10
Volume flow70 – 80 m3/h
Dispensing tool    
Random measurement error (1 µL)1,2≤3 %≤3 %≤3 %≤3 %
Random measurement error (1,000 µL)1,2≤0.15 %≤0.15 %≤0.15 %≤0.15 %
Random measurement error (50 µL)1,2≤0.4 %≤0.4 %≤0.4 %≤0.4 %
Systematic measurement error (1 µL)1,2±5 %±5 %±5 %±5 %
Systematic measurement error (1,000 µL)1,2±0.7 %±0.7 %±0.7 %±0.7 %
Systematic measurement error (50 µL)1,2±1.2 %±1.2 %±1.2 %±1.2 %
1in pipetting mode, free jet, without pre-wetting, with distilled water, at 20 °C
2See Eppendorf Application Note 168 for typical pipetting performance